금속 스테인리스 스틸 구조용 스테인리스 스틸

구조용 스테인리스 스틸

Specifications

Guidelines for the selection of the correct stainless steel grade in structural applications according to the service environment: Euro Codes 1 to 4 provide a procedure for selecting the appropriate grade of stainless steel for the service environment of structural members. The environment is assessed using Corrosion Resistance Factor (CRF) and the stainless grades are placed in Corrosion Resistance Classes (CRC) I, I, III, IV & V according to CRF value.

Calculation of Corrosion Resistance Factor (CRF)

The Corrosion Resistance Factor is comprised of three elements: F1, F2 & F3.

Calculation of F1: Risk of Exposure to Chlorides

F1 Value Description
1 Internal, Controlled Environment
0 Low Risk of Exposure: M.10km or S>0.1km
-3 Medium Risk of Exposure: 1km
-7 High Risk of Exposure: 0.25km
-10 Very High Risk of Exposure: Road Tunnels where de-icing salts used
-10 Very High Risk of Exposure: M<0.25km: North Sea Coast of Germany & All Baltic Coastal Areas
-15 Very High Risk of Exposure: M<0.25km - Incl All other European/UK Coastal Areas

M is distance from sea. S is distance from roads where de-icing salts are used

Calculation of F2: Risk of Exposure to Sulphur Dioxide

F2 Value Description
0 Low Risk of Exposure: 10 average deposition
-5 Medium Risk of Exposure: 10-90 average deposition
-10 High Risk of Exposure: 90-250 average deposition

Note: In European coastal environments the SO2 value is usually low. For inland environments the value is either low or medium. High values are usually associated with heavily industrialised locations or specific environments such as tunnels. In the table the deposition values are given in the units micro-grams per m3.

Calculation of F3: Cleaning or Rain Washing

F3 Value Description
0 Fully Exposed to Washing by Rain
-2 Specified Cleaning Regime
-7 No Washing by Rain or Specified Cleaning Regime

For Cold rolled stainless steel the old BS1449 standard has been replaced by two EN Standards:

Calculation of CRC

The Corrosion Resistance Class (CRC) required for the given environment is given by first calculating the Corrosion Resistance Factor (CRF) through adding F1+F2+F3.

Corrosion Resistance Class (CRC)

CRF CRC
1 I
0 to under -7 II
-7 to under -15 III
-15 to under -20 IV
Over -20 V

An appropriate stainless steel grade for the environment can now be chosen from the table below showing the CRC for the various commonly available grades.

CRC By Grade

CRC Class Grades
I (Ferritic) 1.4003, 1.4016 (430), 1.4512 (409)
II (Standard 18/8 Austenitic) 1.4301 (304), 1.4307 (304L), 1.4311, 1.4541, 1.4318, 1.4306, 1.4567, 1.4482
III (Mo-Austenitic & Lean Duplex) 1.4410, 1.4404, 1.4435, 1.4571, 1.4429, 1.4432, 1.4578, 1.4462, 1.4362, 1.4062, 1.4162
IV (Super-Austenitic & Duplex) 1.4439, 1.4539, 1.4462
V (Super-Austenitic & Duplex) 1.4565, 1.4529, 1.4547, 1.4410, 1.4501, 1.4507

필요한 제품 검색

중국 내 광범위한 서비스 센터 네트워크와 강력한 처리 시설의 지원을 받습니다.

스테인리스 스틸

면책 조항

이 데이터는 참고용일 뿐이므로 전체 사양을 대신하여 의존해서는 안 됩니다. 특히 기계적 특성 요구 사항은 성질, 제품 및 제품 치수에 따라 크게 달라집니다. 모든 정보는 당사의 현재 지식을 기반으로 하며 선의로 제공됩니다. 당사는 제3자가 이에 의존하여 취한 조치와 관련하여 어떠한 책임도 지지 않습니다. 위에 표시된 ‘데이터시트 업데이트’ 날짜는 데이터시트의 정확성 또는 최신 여부를 보장하지 않는다는 점에 유의하시기 바랍니다.

본 데이터시트에 제공된 정보는 EN 표준, 공인된 업계 참고자료(온라인 인쇄물), 제조업체 데이터 등 다양한 공인 출처에서 발췌한 것입니다. 이러한 출처의 최신 정보 또는 출처의 정확성에 대한 보장은 제공되지 않습니다. 회사에서 제공하는 자료는 이 데이터와 크게 다를 수 있지만 모든 관련 및 적용 가능한 표준을 준수합니다. 설명된 제품은 다양한 용도로 사용될 수 있으며 회사는 그 사용을 통제할 수 없으므로 회사는 명시적이든 묵시적이든 크기, 속성 및/또는 특정 목적에의 적합성에 대해 법령 또는 기타 방식으로 명시적이든 묵시적이든 모든 조건이나 보증을 구체적으로 배제합니다. 회사가 제3자에게 제공하는 조언은 해당 당사자의 도움을 위해서만 제공되며 회사는 이에 대한 책임이 없습니다. 모든 거래는 회사의 현재 판매 약관의 적용을 받습니다. 고객에 대한 회사의 책임 범위는 해당 약관에 명확하게 명시되어 있으며, 요청 시 사본을 제공해 드립니다.