TRANG CHỦ KIM LOẠI THÉP KHÔNG GỈ Khả năng chống ăn mòn của thép không gỉ

Khả năng chống ăn mòn của thép không gỉ

Lựa chọn đúng loại thép không gỉ là yếu tố quan trọng để tránh các vấn đề về ăn mòn.

Corrosion can be defined as the attack of a metallic material by its environment. Stainless steels all possess a high resistance to corrosion. This resistance is conferred by the naturally occurring chromium – rich oxide film which is always present on the surface of stainless steel. Although less than 130 Angstrom thick (1 Angstrom unit = 10-8 cm) this invisible film is extremely protective as it is inert and adheres tightly to the metal. The oxide film has the unique property of self-repair which is unattainable in applied films. This means that if the film is removed or damaged or a new metal surface is created by cutting then in the atmosphere or other source of oxygen the protection will be instantaneously re-established. The more highly alloyed grades of stainless steel possess the best corrosion resistance and are able to withstand more aggressive environments.

Corrosion Resistance

Corrosion takes many different forms. Its initiation and subsequent rate of progress is affected in varying degrees by numerous material and environmental factors. A comprehensive assessment of the exact ‘corrosion resistance’ of a material is therefore difficult. However, corrosion tables covering a vast range of stainless steels and environments are available.

Oxidation

Oxidation is the combination of a metal with oxygen to form the metal oxide which occurs in dry conditions. When this process is ongoing the whole of the metal may be converted. Stainless steels are oxidation resistant, even at elevated temperatures. Special heat resisting grades, such as type 310, are operated at temperatures of up to 1100°C.

Pickling & Passivation

To achieve optimum corrosion performance stainless steel must go into service fully passivated. Its protective surface oxide layer must be intact and uncontaminated. In particular weld tint and any fabrication debris must be removed. It is particularly important to remove any carbon or mild steel contamination. This is done using proprietary solutions, chemical and pastes based on nitric acid or a mixture of nitric and hydrofluoric acids.

Design Criteria

To achieve optimum corrosion performance care must betaken at the design stage. In particular design should employ smooth contours and radiused corners whilst avoiding sharp edges and crevices. Design should also promote material flow and mixing to avoid localised concentrations and/or stagnant conditions. Other considerations are ease of cleaning and maintenance as well as avoidance of dissimilar metal contact.

Forms of Corrosion

There are many different forms of corrosion. General Corrosion is the uniform overall attack of a component across its whole surface. It is avoided by correct grade selection.

Pitting Corrosion

A highly localised attack seen as small spots across a surface occurring mainly at sites of metallurgical heterogeneity. Particularly prevalent in chloride environments, especially if oxyqen is in plentiful supply, it can lead to perforation. Higher Chromium, Nickel and Molybdenum contents improve pitting resistance, thus type 316 is extensively used in such situations. Laboratory tests can be carried out to confirm pitting resistance such as ASTM G48-03. The Pitting Resistance Equivalent (PRE) number can be calculated and gives a good indication of the resistance to pitting:

Austenitic Stainless Steel: PRE = (%Cr) + (3.3 x %Mo) + (16 x %Ni)

Duplex Stainless Steel: PRE = (%Cr) + (3.3 x %Mo) + (30 x %Ni)

Atmospheric Corrosion

This occurs due to the attack from oxygen, water and the pollutants therein such as chlorides, sulphur compounds and solids. The problem is particularly prevalent in coastal, industrial and highly polluted areas where necessitates the use of type 316 is recommended for outdoor applications in such environments.

Acid Corrosion

Occurs due to aggressive attack by acids which may be accelerated by the presence of other chemicals. A large number of acid environments are resisted by stainless steels – resistance to oxidising solutions is very good provided the correct grade is used.

Galvanic Corrosion

Covers situations where attack is caused by a potential difference. This potential difference can be set up in a number of ways including contact between dissimilar metals in an aqueous or conducting solution, differential aeration (variation in oxygen concentration) and local variations in concentration of the solution. Correct material selection and good design can eliminate this.

Waterline Corrosion

This is a form of galvanic corrosion taking place at the surface of a liquid in which the stainless steel is partially immersed.

Crevice Corrosion

Occurs in crevices such as joints, cavities, holes, corners, grooves, slots, gaskets and gaps between components. It is caused by the breakdown on the protective oxide layer, normally in reducing environments and can be seen as another types of galvanic corrosion. Good design should be used to eliminate such crevices and thus avoid this phenomenon.

Stress Corrosion Cracking (SCC)

Occurs in austenitic stainless steels when they are operated under tensional stress in chloride environments at temperatures in excess of about 60°C. The stress could arise through in-service loading, pressurisation of pipework and vessels or as residual stress from cold working. Nickel content assists resistance to SCC and thus grade 316 is more resistant to this form of attack than 304, whilst the duplex grades such as 2205 perform very well. Ferritic stainless steels are immune to this form of attack.

Sulphide Stress Corrosion (SSC)

This is another form of stress corrosion cracking that can occur in environments containing both chlorides and hydrogen sulphide (H2S). It is of particular concern in the off- shore oil and gas industry.

Bacterial Corrosion

Occurs due to the presence and activity of certain types of bacteria and tends to be localised, for example in crevices. It is overcome by good design, continuous flow and regular cleaning.

Inter-Granular Corrosion

Occurs in austenitic stainless steels and is a rapid and localized phenomenon. Called sensitization, it is caused by chromium carbide precipitation at grain boundaries which depletes the surrounding area of chromium thus reducing its corrosion resistance. This may be caused by incorrect heat treatment, heat input during welding, service in the temperature range 450 to 850°C or service at a higher temperature and slow cooling through this range. Modern steelmaking, correct grade selection and post weld heat treatment prevents this occurring. Various types of stainless steel can be considered to avoid the problem including extra low carbon grades and titanium (321 & 316Ti) or niobium (347) bearing grades.

Weld Decay

This is a form of intergranular corrosion occurring in the heat-affected zone of the parent metal parallel to the weld. Susceptibility to this attack is assessed using one of these standard tests:

  • Test as given in BS1449/BS1501 using boiling copper sulphate/sulphuric acid
  • Test as given in ASTM A262 Practice C using boiling nitric acid. Low carbon grades perform better in the more severe (latter) test.

Fretting Corrosion

Can also be called corrosion-abrasion and is caused by continuous removal of corrosion product due to surfaces rubbing together, which leads to progressive wasting of material. Stainless steels do not suffer from this form of attack.

Tìm kiếm sản phẩm bạn cần

Mạng lưới rộng khắp các trung tâm dịch vụ tại Trung Quốc, được hỗ trợ bởi các cơ sở sản xuất hiện đại.

Cắt CNC

LƯU Ý

Thông tin này chỉ mang tính chất tham khảo và do đó không nên được sử dụng thay thế cho bản thông số kỹ thuật đầy đủ. Đặc biệt, các yêu cầu về tính chất cơ học có thể thay đổi đáng kể tùy thuộc vào nhiệt độ, sản phẩm và kích thước sản phẩm. Tất cả thông tin được cung cấp dựa trên kiến thức hiện tại của chúng tôi và được cung cấp với thiện chí. Công ty sẽ không chịu trách nhiệm đối với bất kỳ hành động nào của bên thứ ba dựa trên thông tin này. Lưu ý rằng ngày ‘Cập nhật bảng dữ liệu’ được hiển thị ở trên không đảm bảo tính chính xác hoặc liệu bảng dữ liệu có được cập nhật hay không.

Thông tin được cung cấp trong bảng dữ liệu này được trích dẫn từ các nguồn được công nhận, bao gồm Tiêu chuẩn EN, các tài liệu tham khảo ngành được công nhận (bản in và trực tuyến) và dữ liệu của nhà sản xuất. Công ty không đảm bảo rằng thông tin này được lấy từ phiên bản mới nhất của các nguồn đó hoặc về độ chính xác của các nguồn đó. Vật liệu do Công ty cung cấp có thể khác biệt đáng kể so với dữ liệu này nhưng sẽ tuân thủ tất cả các tiêu chuẩn liên quan và áp dụng. Do các sản phẩm được mô tả có thể được sử dụng cho nhiều mục đích khác nhau và Công ty không kiểm soát được cách sử dụng của chúng; Công ty đặc biệt loại trừ tất cả các điều kiện hoặc bảo đảm, dù được thể hiện rõ ràng hay ngụ ý theo luật hoặc theo cách khác, liên quan đến kích thước, tính chất và/hoặc sự phù hợp cho bất kỳ mục đích cụ thể nào, dù được thể hiện rõ ràng hay ngụ ý. Lời khuyên do Công ty cung cấp cho bất kỳ bên thứ ba nào chỉ nhằm mục đích hỗ trợ cho bên đó và Công ty không chịu trách nhiệm pháp lý nào. Tất cả các giao dịch đều tuân theo Điều kiện Bán hàng hiện hành của Công ty. Phạm vi trách nhiệm của Công ty đối với bất kỳ khách hàng nào được quy định rõ ràng trong các Điều kiện đó; bản sao của các Điều kiện này có thể được yêu cầu cung cấp.

Nếu bạn có bất kỳ câu hỏi nào, vui lòng liên hệ với chúng tôi, chúng tôi luôn sẵn sàng hỗ trợ 24/7.